Skip to product information
1 of 10

Kohler

Kohler 100KW 120/208V 3-Phase Standby Generator Aluminum New - KG100R-QS5

Kohler 100KW 120/208V 3-Phase Standby Generator Aluminum New - KG100R-QS5

1 Review

Only left!

image

Free Delivery

image

Limited Stocks

In Stock - Ready to be Shipped

Regular price Sale price $41,649.00
Shipping calculated at checkout.

Quantity

View full details
SALE ENDS IN
07 HRS
23 MINS
28 SECS
DON'T MISS IT!

Popular Add on

$100.00

$30.00

$200.00

$70.00

Add-Ons Bundle

$100.00

$30.00

$200.00

$70.00

Bundle Offer

$300.00

$100.00

Recently Viewed

Kohler  100KW 120/208V 3-Phase Standby Generator Aluminum New - KG100R-QS5

Reliable power for very large residential or small business needs. Built to weather the storms, our largest natural gas/liquid propane generators with industrial-grade engines keep your family comfortable and your business running when a utility failure or storm knocks out power

What our Experts Think
  • True commercial standby power (100 kW output)
    Built for 120/208 V 3‑phase systems, this generator is engineered to support large commercial buildings, data centers, heavy electrical loads, or large residential service panels that demand consistent three‑phase backup.
  • Industrial‑grade liquid‑cooled performance
    Powered by a Kohler 6.2 L liquid‑cooled turbocharged engine with hydraulic valve lifters, delivering durable, quieter, and fuel‑efficient operation at 1800 RPM.
  • Clean, stable power quality for sensitive loads
    Advanced APM402 controller with ±0.5 % voltage regulation and low harmonic distortion ensures clean power—protecting sensitive electronics, servers, and precision equipment even under heavy loads.
  • Fast automatic response (≈10 sec)
    The Fast‑Response® excitation system brings the generator up to full load quickly during outages, reducing downtime for critical operations.
  • Rugged aluminum enclosure with weather resilience
    Sound‑attenuating aluminum housing with up to 186 mph wind load rating and corrosion‑resistant finish makes it suitable for outdoor installations in severe weather.
  • Pre‑installed block heater
    Improves cold‑start reliability and warm‑up times, key for standby readiness in varying climates.
  • Remote monitoring capable (optional)
    The APM402 controller supports advanced monitoring and diagnostics, including remote communication with network/serial interfaces when paired with optional systems.
  • Dual‑fuel flexibility (natural gas & LP)
    Runs on both natural gas and liquid propane with simple field conversion, offering fuel flexibility and operational continuity.

Q&A

Q: What power capacity does this generator provide?
A: It delivers 100 kW of continuous standby power at 120/208 V three‑phase, ideal for large commercial buildings and mission‑critical backup applications.

Q: What type of facilities is it best suited for?
A: Designed for commercial, institutional, and large residential 3‑phase systems, providing reliable backup for HVAC, lighting, servers, and other essential loads during outages.

Q: What fuel options are supported?
A: Runs on natural gas or liquid propane (LP) with simple field conversion while maintaining emissions certification.

Q: What engine and control features does it include?
A: Equipped with an industrial‑grade Kohler 6.2 L liquid‑cooled engine and advanced APM402 digital controller for voltage/frequency regulation, diagnostics, and remote monitoring.

Q: How fast can it restore power?
A: It can handle full electrical loads and restore power within ≈10 seconds when matched with an automatic transfer switch (sold separately).

Q: How clean and stable is the output?
A: Provides exceptional voltage & frequency regulation with ultra‑low total harmonic distortion, safe for sensitive electronics and critical equipment.

Q: How quiet and durable is the unit?
A: The aluminum sound‑attenuated enclosure with 186 mph wind rating and acoustic insulation keeps noise low (~69 dB at 7 m) and resists corrosion and weather.


Maintenance Tips
  • Regular Oil & Filter Changes: Change engine oil and filters every 100–200 hours or annually to protect the industrial liquid‑cooled engine and reduce wear.
  • Coolant System Maintenance: Check coolant levels regularly and flush the cooling system as recommended to prevent overheating of the liquid‑cooled engine.
  • Monitor Controller & Diagnostics: Use the APM402 controller’s diagnostics to track performance, log faults, and schedule preventive service.
  • Air Filter & Ignition Checks: Inspect and replace air filters and spark plugs routinely for efficient combustion, clean starts, and fuel economy.
  • Weekly Exercise Runs: Run automatic weekly exercise cycles to keep engine components lubricated and the generator ready for outages.
  • Load Testing: Periodically run under load to confirm stable voltage and frequency output for sensitive electronics and peak performance.
  • Fuel System Inspection (NG/LP): Ensure clean supply lines and consistent fuel pressure for uninterrupted backup power.
  • Battery & Electrical Connections: Check battery charge, cables, and terminals; clean and tighten for reliable automatic starts.
  • Enclosure Care: Keep the aluminum enclosure clean and clear of debris to promote airflow and prevent corrosion.