{"product_id":"kohler-kg80r-qs-80kw-120-240v-single-phase-standby-generator-steel-new","title":"Kohler  80KW 120\/240V Single Phase Standby Generator Steel New - KG80R-QS","description":"\u003ch2\u003e\u003cspan\u003eKohler  80KW 120\/240V Single Phase Standby Generator Steel New - KG80R-QS\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eReliable power for very large residential or small business needs. Built to weather the storms, hard-working 80 kW KOHLER generators with industrial-grade engines keep your family comfortable and your business running when a utility failure or storm knocks out power.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\n\u003cbr\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-end=\"387\" data-start=\"27\" data-section-id=\"i4np3z\"\u003e\n\u003cstrong data-end=\"69\" data-start=\"29\"\u003eCommercial‑class 80 kW standby power\u003c\/strong\u003e\u003cbr data-end=\"72\" data-start=\"69\"\u003eThe \u003cstrong data-end=\"119\" data-start=\"78\"\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eKohler 80 kW 120\/240 V Standby Generator (KG80R‑QS)\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e delivers robust \u003cstrong data-is-only-node=\"\" data-end=\"169\" data-start=\"136\"\u003e120\/240 V single‑phase backup\u003c\/strong\u003e, ideal for \u003cstrong data-end=\"281\" data-start=\"181\"\u003every large homes, light commercial spaces, small business electrical systems, and critical loads\u003c\/strong\u003e that require dependable emergency power when utility service fails. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"686\" data-start=\"389\" data-section-id=\"1747jss\"\u003e\n\u003cstrong data-end=\"432\" data-start=\"391\"\u003eIndustrial‑grade liquid‑cooled engine\u003c\/strong\u003e\u003cbr data-end=\"435\" data-start=\"432\"\u003eEquipped with a \u003cstrong data-end=\"490\" data-start=\"453\"\u003eKohler 6.2 L liquid‑cooled engine\u003c\/strong\u003e running at \u003cstrong data-is-only-node=\"\" data-end=\"514\" data-start=\"502\"\u003e1800 RPM\u003c\/strong\u003e, this unit ensures \u003cstrong data-end=\"609\" data-start=\"534\"\u003ecooler and quieter operation, fuel efficiency, and long‑term durability\u003c\/strong\u003e compared with air‑cooled counterparts. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1001\" data-start=\"688\" data-section-id=\"lpl383\"\u003e\n\u003cstrong data-end=\"728\" data-start=\"690\"\u003eClean and stable electrical output\u003c\/strong\u003e\u003cbr data-end=\"731\" data-start=\"728\"\u003eAdvanced alternator design with \u003cstrong data-end=\"843\" data-start=\"765\"\u003etight voltage\/frequency regulation and ultra‑low total harmonic distortion\u003c\/strong\u003e delivers \u003cstrong data-is-only-node=\"\" data-end=\"868\" data-start=\"853\"\u003eclean power\u003c\/strong\u003e, protecting \u003cstrong data-end=\"934\" data-start=\"881\"\u003esensitive electronics, servers, and smart systems\u003c\/strong\u003e under heavy load conditions. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1256\" data-start=\"1003\" data-section-id=\"12m8uf1\"\u003e\n\u003cstrong data-end=\"1040\" data-start=\"1005\"\u003eFast automatic standby response\u003c\/strong\u003e\u003cbr data-end=\"1043\" data-start=\"1040\"\u003eThe \u003cstrong data-end=\"1087\" data-start=\"1049\"\u003eFast‑Response® X excitation system\u003c\/strong\u003e brings the generator up to full rated load \u003cstrong data-is-only-node=\"\" data-end=\"1153\" data-start=\"1131\"\u003ewithin ~10 seconds\u003c\/strong\u003e of a utility outage, minimizing disruption to critical circuits. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1503\" data-start=\"1258\" data-section-id=\"1gjkjz5\"\u003e\n\u003cstrong data-end=\"1298\" data-start=\"1260\"\u003eAPM402 controller with diagnostics\u003c\/strong\u003e\u003cbr data-end=\"1301\" data-start=\"1298\"\u003eProvides \u003cstrong data-end=\"1424\" data-start=\"1312\"\u003eadvanced controller functions, local display data, diagnostics, and optional remote communication interfaces\u003c\/strong\u003e, simplifying monitoring and maintenance. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1787\" data-start=\"1505\" data-section-id=\"1m7p6px\"\u003e\n\u003cstrong data-end=\"1555\" data-start=\"1507\"\u003eRugged steel enclosure with acoustic control\u003c\/strong\u003e\u003cbr data-end=\"1558\" data-start=\"1555\"\u003e\u003cstrong data-end=\"1595\" data-start=\"1560\"\u003eSound‑attenuating steel housing\u003c\/strong\u003e with corrosion‑resistant finish and internal silencers keeps noise around \u003cstrong data-end=\"1686\" data-start=\"1670\"\u003e≈68 dB @ 7 m\u003c\/strong\u003e, making it feasible for outdoor placement near occupied areas. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2020\" data-start=\"1789\" data-section-id=\"bdqnry\"\u003e\n\u003cstrong data-end=\"1824\" data-start=\"1791\"\u003eDual‑fuel flexibility (NG\/LP)\u003c\/strong\u003e\u003cbr data-end=\"1827\" data-start=\"1824\"\u003eOperates on \u003cstrong data-end=\"1879\" data-start=\"1841\"\u003enatural gas or liquid propane (LP)\u003c\/strong\u003e with simple field conversion—allowing installation flexibility and continuity during extended outages. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2209\" data-start=\"2022\" data-section-id=\"y2ycyf\"\u003e\n\u003cstrong data-end=\"2054\" data-start=\"2024\"\u003ePre‑installed block heater\u003c\/strong\u003e\u003cbr data-end=\"2057\" data-start=\"2054\"\u003eImproves \u003cstrong data-end=\"2111\" data-start=\"2068\"\u003ecold‑weather starting and warm‑up times\u003c\/strong\u003e, enhancing reliability in climates with lower temperatures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e\n\u003cbr\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-end=\"325\" data-start=\"62\"\u003e\u003cstrong data-end=\"121\" data-start=\"62\"\u003eQ: What power output does this 80 kW generator provide?\u003c\/strong\u003e\u003cbr data-end=\"124\" data-start=\"121\"\u003eA: It delivers \u003cstrong data-end=\"159\" data-start=\"139\"\u003e80 kW (80,000 W)\u003c\/strong\u003e of continuous standby power at \u003cstrong data-end=\"217\" data-start=\"191\"\u003e120\/240 V single‑phase\u003c\/strong\u003e, perfect for \u003cstrong data-end=\"286\" data-start=\"231\"\u003every large homes or light commercial backup systems\u003c\/strong\u003e. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"534\" data-start=\"327\"\u003e\u003cstrong data-end=\"356\" data-start=\"327\"\u003eQ: What fuel does it use?\u003c\/strong\u003e\u003cbr data-end=\"359\" data-start=\"356\"\u003eA: It runs on \u003cstrong data-end=\"425\" data-start=\"373\"\u003eclean‑burning natural gas or liquid propane (LP)\u003c\/strong\u003e with simple field conversion while maintaining emission certification. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"847\" data-start=\"536\"\u003e\u003cstrong data-end=\"601\" data-start=\"536\"\u003eQ: What type of engine and performance features are included?\u003c\/strong\u003e\u003cbr data-end=\"604\" data-start=\"601\"\u003eA: It’s powered by an \u003cstrong data-end=\"680\" data-start=\"626\"\u003eindustrial‑grade Kohler 6.2 L liquid‑cooled engine\u003c\/strong\u003e with hydraulic valve lifters, and has \u003cstrong data-end=\"748\" data-start=\"719\"\u003eadvanced power regulation\u003c\/strong\u003e for clean, stable output with ultra‑low harmonic distortion. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1078\" data-start=\"849\"\u003e\u003cstrong data-end=\"901\" data-start=\"849\"\u003eQ: How quickly does it respond to power outages?\u003c\/strong\u003e\u003cbr data-end=\"904\" data-start=\"901\"\u003eA: When paired with an \u003cstrong data-end=\"956\" data-start=\"927\"\u003eautomatic transfer switch\u003c\/strong\u003e (sold separately), it \u003cstrong data-end=\"1039\" data-start=\"979\"\u003eaccepts full load and restores power in about 10 seconds\u003c\/strong\u003e. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1361\" data-start=\"1080\"\u003e\u003cstrong data-end=\"1134\" data-start=\"1080\"\u003eQ: How durable and weather‑ready is the enclosure?\u003c\/strong\u003e\u003cbr data-end=\"1137\" data-start=\"1134\"\u003eA: The \u003cstrong data-end=\"1181\" data-start=\"1144\"\u003esound‑attenuating steel enclosure\u003c\/strong\u003e has a corrosion‑resistant powder‑baked finish and internal silencer, keeping noise under ~68 dB at 7 m and ensuring long‑lasting performance. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1632\" data-start=\"1363\"\u003e\u003cstrong data-end=\"1420\" data-start=\"1363\"\u003eQ: What control and monitoring features are included?\u003c\/strong\u003e\u003cbr data-end=\"1423\" data-start=\"1420\"\u003eA: It comes with a \u003cstrong data-end=\"1470\" data-start=\"1442\"\u003eKohler APM402 controller\u003c\/strong\u003e for system monitoring, diagnostics, and remote communication via PC\/network interfaces (remote monitoring sold separately). \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1818\" data-start=\"1634\"\u003e\u003cstrong data-end=\"1668\" data-start=\"1634\"\u003eQ: Is a block heater included?\u003c\/strong\u003e\u003cbr data-end=\"1671\" data-start=\"1668\"\u003eA: Yes — a \u003cstrong data-end=\"1712\" data-start=\"1682\"\u003epre‑installed block heater\u003c\/strong\u003e supports easier starting and quicker warm‑ups in cooler conditions.\u003c\/p\u003e\n\u003ch5\u003e\n\u003cbr\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-end=\"447\" data-start=\"230\" data-section-id=\"sfv6kt\"\u003e\n\u003cstrong data-end=\"265\" data-start=\"232\"\u003eRegular Oil \u0026amp; Filter Changes:\u003c\/strong\u003e Change engine oil and filters every \u003cstrong data-end=\"331\" data-start=\"302\"\u003e100–200 hours or annually\u003c\/strong\u003e to protect the industrial V‑8 liquid‑cooled engine and extend service life. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"633\" data-start=\"448\" data-section-id=\"1pkyypy\"\u003e\n\u003cstrong data-end=\"476\" data-start=\"450\"\u003eCoolant System Checks:\u003c\/strong\u003e Maintain proper coolant level and flush periodically to prevent overheating and ensure efficient cooling under load. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"827\" data-start=\"634\" data-section-id=\"qhf6yd\"\u003e\n\u003cstrong data-end=\"676\" data-start=\"636\"\u003eController \u0026amp; Diagnostics Monitoring:\u003c\/strong\u003e Use the \u003cstrong data-end=\"706\" data-start=\"685\"\u003eAPM402 controller\u003c\/strong\u003e to review system diagnostics, check fault logs, and plan preventive maintenance. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"992\" data-start=\"828\" data-section-id=\"nmwuku\"\u003e\n\u003cstrong data-end=\"863\" data-start=\"830\"\u003eAir Filter \u0026amp; Ignition Checks:\u003c\/strong\u003e Inspect and replace air filters and spark plugs regularly to ensure efficient combustion, reliable starting, and fuel economy.\u003c\/li\u003e\n\u003cli data-end=\"1150\" data-start=\"993\" data-section-id=\"exuld5\"\u003e\n\u003cstrong data-end=\"1020\" data-start=\"995\"\u003eWeekly Exercise Runs:\u003c\/strong\u003e Run automatic or manual exercise cycles weekly to keep internal components lubricated and avoid moisture buildup in the engine.\u003c\/li\u003e\n\u003cli data-end=\"1337\" data-start=\"1151\" data-section-id=\"1mmofj3\"\u003e\n\u003cstrong data-end=\"1170\" data-start=\"1153\"\u003eLoad Testing:\u003c\/strong\u003e Periodically test under \u003cstrong data-end=\"1210\" data-start=\"1195\"\u003eactual load\u003c\/strong\u003e to confirm stable \u003cstrong data-end=\"1249\" data-start=\"1229\"\u003e120\/240 V output\u003c\/strong\u003e and frequency regulation for sensitive devices. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1470\" data-start=\"1338\" data-section-id=\"b62skj\"\u003e\n\u003cstrong data-end=\"1376\" data-start=\"1340\"\u003eFuel System Maintenance (NG\/LP):\u003c\/strong\u003e Check fuel lines and pressure for clean, consistent delivery to prevent performance issues.\u003c\/li\u003e\n\u003cli data-end=\"1636\" data-start=\"1471\" data-section-id=\"1444pp3\"\u003e\n\u003cstrong data-end=\"1510\" data-start=\"1473\"\u003eBattery \u0026amp; Electrical Connections:\u003c\/strong\u003e Verify battery charge, clean terminals, and tighten connections for reliable automatic starts and controller communication.\u003c\/li\u003e\n\u003cli data-end=\"1822\" data-start=\"1637\" data-section-id=\"bvjk4a\"\u003e\n\u003cstrong data-end=\"1672\" data-start=\"1639\"\u003eEnclosure \u0026amp; Ventilation Care:\u003c\/strong\u003e Keep the steel sound‑attenuating enclosure clean and free of debris to promote airflow and prevent corrosion.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kohler","offers":[{"title":"Default Title","offer_id":45506021654665,"sku":"KG80R-QS","price":33299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0759\/2443\/9177\/files\/2-removebg_0b0e23f8-c562-423b-a447-abf80858daa0.png?v=1775896446","url":"https:\/\/paw-counter.com\/products\/kohler-kg80r-qs-80kw-120-240v-single-phase-standby-generator-steel-new","provider":"Paw Counter","version":"1.0","type":"link"}