{"product_id":"kohler-60rclb-qs6-60kw-120-208v-3-phase-standby-generator-with-app-connect-new","title":"Kohler  60KW 120\/208V 3-Phase Standby Generator with App Connect New - 60RCLB-QS6","description":"\u003ch2\u003e\u003cspan\u003eKohler  60KW 120\/208V 3-Phase Standby Generator with App Connect New - 60RCLB-QS6\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eReliable power for large residential or small business needs. When the power goes out during a bad storm or power failure, your 60 kW KOHLER generator with industrial-grade engine keeps your home or business – from central air to sump pump to personal computers – up and running.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-end=\"300\" data-start=\"27\" data-section-id=\"9ypvv2\"\u003e\n\u003cstrong data-end=\"72\" data-start=\"29\"\u003ePowerful 48 kW 3-phase standby solution\u003c\/strong\u003e\u003cbr data-end=\"75\" data-start=\"72\"\u003eDelivers \u003cstrong data-end=\"113\" data-start=\"86\"\u003e50 kW (LP) \/ 48 kW (NG)\u003c\/strong\u003e of three-phase power—ideal for \u003cstrong data-is-only-node=\"\" data-end=\"225\" data-start=\"145\"\u003elarge homes, commercial buildings, light industrial sites, or critical loads\u003c\/strong\u003e requiring robust backup performance. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"556\" data-start=\"302\" data-section-id=\"d149tt\"\u003e\n\u003cstrong data-end=\"345\" data-start=\"304\"\u003eIndustrial-grade liquid-cooled engine\u003c\/strong\u003e\u003cbr data-end=\"348\" data-start=\"345\"\u003eEquipped with a \u003cstrong data-end=\"407\" data-start=\"366\"\u003e6.2 L liquid-cooled industrial engine\u003c\/strong\u003e that runs at 1800 RPM for \u003cstrong data-is-only-node=\"\" data-end=\"499\" data-start=\"434\"\u003efuel efficiency, quieter operation, and long-term reliability\u003c\/strong\u003e under heavy loads. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"811\" data-start=\"558\" data-section-id=\"1iq9l6v\"\u003e\n\u003cstrong data-end=\"595\" data-start=\"560\"\u003eApp-connected remote monitoring\u003c\/strong\u003e\u003cbr data-end=\"598\" data-start=\"595\"\u003eReal-time alerts and remote status tracking via the \u003cstrong data-end=\"684\" data-start=\"652\"\u003eKohler Energy Management App\u003c\/strong\u003e add convenience and proactive oversight—helpful for facility managers and remote owners. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1116\" data-start=\"813\" data-section-id=\"1vky9tm\"\u003e\n\u003cstrong data-end=\"864\" data-start=\"815\"\u003eFast automatic response \u0026amp; clean power quality\u003c\/strong\u003e\u003cbr data-end=\"867\" data-start=\"864\"\u003eAdvanced excitation and regulation deliver \u003cstrong data-end=\"970\" data-start=\"912\"\u003estable voltage and frequency with ultra-low distortion\u003c\/strong\u003e, protecting sensitive electronics and ensuring \u003cstrong data-is-only-node=\"\" data-end=\"1057\" data-start=\"1018\"\u003efull-load pickup within ~10 seconds\u003c\/strong\u003e of outage detection. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1360\" data-start=\"1118\" data-section-id=\"1u3i1xg\"\u003e\n\u003cstrong data-end=\"1157\" data-start=\"1120\"\u003eQuiet, durable aluminum enclosure\u003c\/strong\u003e\u003cbr data-end=\"1160\" data-start=\"1157\"\u003eSound-attenuating housing keeps noise low (~61 dB @ 7 m) while the \u003cstrong data-end=\"1276\" data-start=\"1229\"\u003ecorrosion-resistant finish and rugged build\u003c\/strong\u003e support outdoor installation near structures. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1610\" data-start=\"1362\" data-section-id=\"1mgh7uj\"\u003e\n\u003cstrong data-end=\"1407\" data-start=\"1364\"\u003eFlexible fuel \u0026amp; installation advantages\u003c\/strong\u003e\u003cbr data-end=\"1410\" data-start=\"1407\"\u003eRuns on \u003cstrong data-end=\"1453\" data-start=\"1420\"\u003enatural gas or liquid propane\u003c\/strong\u003e with simple field conversion and meets NFPA setback requirements, allowing closer siting and installation flexibility. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1849\" data-start=\"1612\" data-section-id=\"1o7bzmx\"\u003e\n\u003cstrong data-end=\"1651\" data-start=\"1614\"\u003eAdvanced controller \u0026amp; diagnostics\u003c\/strong\u003e\u003cbr data-end=\"1654\" data-start=\"1651\"\u003eThe \u003cstrong data-end=\"1679\" data-start=\"1660\"\u003eRDC2 controller\u003c\/strong\u003e provides detailed local data, system diagnostics, and integration with transfer switches for streamlined operation and maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e\n\u003cbr\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-end=\"362\" data-start=\"93\"\u003e\u003cstrong data-end=\"137\" data-start=\"93\"\u003eQ1: What is this generator designed for?\u003c\/strong\u003e\u003cbr data-end=\"140\" data-start=\"137\"\u003eA: A 48 kW 120\/208 V 3-phase standby generator is ideal for commercial buildings, small businesses, and large homes with three-phase electrical service needing dependable backup power. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"570\" data-start=\"364\"\u003e\u003cstrong data-end=\"411\" data-start=\"364\"\u003eQ2: Does it support automatic backup power?\u003c\/strong\u003e\u003cbr data-end=\"414\" data-start=\"411\"\u003eA: Yes — when paired with an automatic transfer switch (not included), it automatically restores power during outages. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"747\" data-start=\"572\"\u003e\u003cstrong data-end=\"614\" data-start=\"572\"\u003eQ3: What fuel options does it support?\u003c\/strong\u003e\u003cbr data-end=\"617\" data-start=\"614\"\u003eA: It runs on clean-burning natural gas or liquid propane (LP) with simple field conversion. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"938\" data-start=\"749\"\u003e\u003cstrong data-end=\"796\" data-start=\"749\"\u003eQ4: What’s App Connect \/ remote monitoring?\u003c\/strong\u003e\u003cbr data-end=\"799\" data-start=\"796\"\u003eA: The Kohler Energy Management App provides real-time alerts and remote monitoring of system status. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1104\" data-start=\"940\"\u003e\u003cstrong data-end=\"979\" data-start=\"940\"\u003eQ5: How much power does it deliver?\u003c\/strong\u003e\u003cbr data-end=\"982\" data-start=\"979\"\u003eA: Rated at approximately 48 kW on natural gas and 50 kW on LP at 120\/208 V 3-phase. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1335\" data-start=\"1106\"\u003e\u003cstrong data-end=\"1164\" data-start=\"1106\"\u003eQ6: Is the power quality good for sensitive equipment?\u003c\/strong\u003e\u003cbr data-end=\"1167\" data-start=\"1164\"\u003eA: Yes — excellent voltage and frequency regulation with ultra-low total harmonic distortion (THD) protects sensitive electronics. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1512\" data-start=\"1337\"\u003e\u003cstrong data-end=\"1361\" data-start=\"1337\"\u003eQ7: How quiet is it?\u003c\/strong\u003e\u003cbr data-end=\"1364\" data-start=\"1361\"\u003eA: Sound-attenuating aluminum enclosure with internal silencer and insulation keeps noise under ~61 dB at 7 m. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1721\" data-start=\"1514\"\u003e\u003cstrong data-end=\"1560\" data-start=\"1514\"\u003eQ8: What engine and controls are included?\u003c\/strong\u003e\u003cbr data-end=\"1563\" data-start=\"1560\"\u003eA: It uses a liquid-cooled Kohler 6.2 L industrial engine with the RDC2 controller for advanced diagnostics and control.\u003c\/p\u003e\n\u003ch5\u003e\n\u003cbr\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-end=\"248\" data-start=\"101\" data-section-id=\"1te345h\"\u003e\n\u003cstrong data-end=\"132\" data-start=\"103\"\u003eRun Weekly Exercise Cycle\u003c\/strong\u003e\u003cbr data-end=\"135\" data-start=\"132\"\u003eKeep the system active with automatic self-tests (≈20–30 minutes) to maintain engine lubrication and readiness.\u003c\/li\u003e\n\u003cli data-end=\"422\" data-start=\"250\" data-section-id=\"iiavif\"\u003e\n\u003cstrong data-end=\"296\" data-start=\"252\"\u003eFollow Oil \u0026amp; Filter Maintenance Schedule\u003c\/strong\u003e\u003cbr data-end=\"299\" data-start=\"296\"\u003eChange engine oil, oil filter, and air filter at recommended intervals to protect the high-performance industrial engine.\u003c\/li\u003e\n\u003cli data-end=\"555\" data-start=\"424\" data-section-id=\"920vhw\"\u003e\n\u003cstrong data-end=\"463\" data-start=\"426\"\u003eInspect Battery \u0026amp; Charger Monthly\u003c\/strong\u003e\u003cbr data-end=\"466\" data-start=\"463\"\u003eEnsure strong battery voltage and clean terminals for fast, reliable automatic startup.\u003c\/li\u003e\n\u003cli data-end=\"698\" data-start=\"557\" data-section-id=\"q4vi04\"\u003e\n\u003cstrong data-end=\"590\" data-start=\"559\"\u003eMonitor Fuel System (NG\/LP)\u003c\/strong\u003e\u003cbr data-end=\"593\" data-start=\"590\"\u003eCheck fuel pressure, regulators, and line integrity for stable 3-phase power delivery under heavy load.\u003c\/li\u003e\n\u003cli data-end=\"832\" data-start=\"700\" data-section-id=\"157fdt7\"\u003e\n\u003cstrong data-end=\"734\" data-start=\"702\"\u003eClean Air Intake \u0026amp; Enclosure\u003c\/strong\u003e\u003cbr data-end=\"737\" data-start=\"734\"\u003eRemove dust, debris, and obstructions to maintain cooling efficiency and prevent overheating.\u003c\/li\u003e\n\u003cli data-end=\"959\" data-start=\"834\" data-section-id=\"rkjt6u\"\u003e\n\u003cstrong data-end=\"868\" data-start=\"836\"\u003eTest Under Load Periodically\u003c\/strong\u003e\u003cbr data-end=\"871\" data-start=\"868\"\u003eSimulate real facility demand to confirm voltage stability and proper phase balancing.\u003c\/li\u003e\n\u003cli data-end=\"1103\" data-start=\"961\" data-section-id=\"lapq8s\"\u003e\n\u003cstrong data-end=\"993\" data-start=\"963\"\u003eUse App Connect Monitoring\u003c\/strong\u003e\u003cbr data-end=\"996\" data-start=\"993\"\u003eTrack alerts, runtime history, and system health remotely for proactive maintenance and reduced downtime.\u003c\/li\u003e\n\u003cli data-end=\"1242\" data-start=\"1105\" data-section-id=\"1ey7et9\"\u003e\n\u003cstrong data-end=\"1140\" data-start=\"1107\"\u003eInspect Electrical Components\u003c\/strong\u003e\u003cbr data-end=\"1143\" data-start=\"1140\"\u003eTighten terminals, breakers, and transfer switch connections to ensure safe and stable operation.\u003c\/li\u003e\n\u003cli data-end=\"1385\" data-start=\"1244\" data-section-id=\"mjg3pg\"\u003e\n\u003cstrong data-end=\"1286\" data-start=\"1246\"\u003eCheck Cooling System (if applicable)\u003c\/strong\u003e\u003cbr data-end=\"1289\" data-start=\"1286\"\u003eVerify coolant levels and airflow for consistent performance in high-demand standby operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kohler","offers":[{"title":"Default Title","offer_id":45506023063689,"sku":"60RCLB-QS6","price":28099.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0759\/2443\/9177\/files\/1-removebg_d7ec6658-85dc-4e43-9e93-7947ada09708.png?v=1775896502","url":"https:\/\/paw-counter.com\/products\/kohler-60rclb-qs6-60kw-120-208v-3-phase-standby-generator-with-app-connect-new","provider":"Paw Counter","version":"1.0","type":"link"}