{"product_id":"kohler-24rcla-qs4-23kw-277-480v-3-phase-standby-generator-with-app-connect-new","title":"Kohler  23KW 277\/480V 3-Phase Standby Generator with App Connect New - 24RCLA-QS4","description":"\u003ch2\u003e\u003cspan\u003eKohler  23KW 277\/480V 3-Phase Standby Generator with App Connect New - 24RCLA-QS4\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eReliable power for large residential or small business needs. When the power goes out during a bad storm or power failure, your 23 kW KOHLER generator with industrial-grade engine keeps your home or business – from central air to sump pump to personal computers – up and running.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"1c33wxs\" data-start=\"27\" data-end=\"329\"\u003e\n\u003cstrong data-start=\"29\" data-end=\"84\"\u003eBalanced 3‑phase standby power for commercial loads\u003c\/strong\u003e\u003cbr data-start=\"84\" data-end=\"87\"\u003eDesigned for \u003cstrong data-start=\"102\" data-end=\"135\"\u003e277\/480 V three‑phase systems\u003c\/strong\u003e, this ≈23 kW generator delivers reliable backup for \u003cstrong data-start=\"188\" data-end=\"253\" data-is-only-node=\"\"\u003ecommercial facilities, workshops, and critical infrastructure\u003c\/strong\u003e connected to medium‑voltage services. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1c309jw\" data-start=\"331\" data-end=\"575\"\u003e\n\u003cstrong data-start=\"333\" data-end=\"369\"\u003eApp Connect real‑time monitoring\u003c\/strong\u003e\u003cbr data-start=\"369\" data-end=\"372\"\u003e\u003cstrong data-start=\"374\" data-end=\"407\"\u003eKOHLER® Energy Management App\u003c\/strong\u003e integration provides \u003cstrong data-start=\"429\" data-end=\"466\"\u003eremote alerts and status tracking\u003c\/strong\u003e, helping you monitor system health and activity without onsite checks. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1s6gcj\" data-start=\"577\" data-end=\"825\"\u003e\n\u003cstrong data-start=\"579\" data-end=\"623\"\u003ePremium liquid‑cooled engine performance\u003c\/strong\u003e\u003cbr data-start=\"623\" data-end=\"626\"\u003eThe \u003cstrong data-start=\"632\" data-end=\"684\"\u003e2.2 L liquid‑cooled industrial engine (1800 RPM)\u003c\/strong\u003e offers \u003cstrong data-start=\"692\" data-end=\"729\" data-is-only-node=\"\"\u003equieter, longer‑lasting operation\u003c\/strong\u003e and superior load handling versus air‑cooled competitors. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"a46w0x\" data-start=\"827\" data-end=\"1057\"\u003e\n\u003cstrong data-start=\"829\" data-end=\"863\"\u003eHigh‑quality electrical output\u003c\/strong\u003e\u003cbr data-start=\"863\" data-end=\"866\"\u003eBrushless alternator and tight voltage\/Hz regulation produce \u003cstrong data-start=\"929\" data-end=\"962\"\u003eultra‑low harmonic distortion\u003c\/strong\u003e, protecting motors, controls, and sensitive electronics. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"8tgoav\" data-start=\"1059\" data-end=\"1249\"\u003e\n\u003cstrong data-start=\"1061\" data-end=\"1096\"\u003eFast automatic standby response\u003c\/strong\u003e\u003cbr data-start=\"1096\" data-end=\"1099\"\u003eAutomatically detects utility failure and \u003cstrong data-start=\"1143\" data-end=\"1168\"\u003estarts within seconds\u003c\/strong\u003e, minimizing downtime for critical systems. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"15uwif5\" data-start=\"1251\" data-end=\"1491\"\u003e\n\u003cstrong data-start=\"1253\" data-end=\"1284\"\u003eQuiet, weather‑ready design\u003c\/strong\u003e\u003cbr data-start=\"1284\" data-end=\"1287\"\u003eSound‑attenuating enclosure remains \u003cstrong data-start=\"1325\" data-end=\"1335\"\u003e\u0026lt;61 dB\u003c\/strong\u003e in normal operation and meets \u003cstrong data-start=\"1366\" data-end=\"1395\" data-is-only-node=\"\"\u003e181 mph wind load ratings\u003c\/strong\u003e, making it suitable for close‑to‑structure installations. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1sseg9a\" data-start=\"1493\" data-end=\"1692\"\u003e\n\u003cstrong data-start=\"1495\" data-end=\"1520\"\u003eDual‑fuel flexibility\u003c\/strong\u003e\u003cbr data-start=\"1520\" data-end=\"1523\"\u003eRuns on \u003cstrong data-start=\"1533\" data-end=\"1566\"\u003enatural gas or liquid propane\u003c\/strong\u003e, allowing integration with existing fuel infrastructure and extended standby readiness. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"xe3b1s\" data-start=\"1694\" data-end=\"1907\"\u003e\n\u003cstrong data-start=\"1696\" data-end=\"1733\"\u003eAdvanced controller \u0026amp; diagnostics\u003c\/strong\u003e\u003cbr data-start=\"1733\" data-end=\"1736\"\u003eThe \u003cstrong data-start=\"1742\" data-end=\"1769\"\u003eRDC2 digital controller\u003c\/strong\u003e offers \u003cstrong data-start=\"1777\" data-end=\"1838\" data-is-only-node=\"\"\u003eLCD readout, programmable exerciser, and built‑in charger\u003c\/strong\u003e, aiding setup and maintenance. \u003cspan class=\"\" data-state=\"delayed-open\" aria-describedby=\"radix-_r_8d_\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e\n\u003cbr\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-start=\"98\" data-end=\"388\"\u003e\u003cstrong data-start=\"98\" data-end=\"144\"\u003eQ: What power does this generator deliver?\u003c\/strong\u003e\u003cbr data-start=\"144\" data-end=\"147\"\u003eA: It delivers \u003cstrong data-start=\"162\" data-end=\"190\"\u003e23 kW (LP) \/ ~21 kW (NG)\u003c\/strong\u003e of continuous standby power at \u003cstrong data-start=\"222\" data-end=\"247\"\u003e277\/480 V three‑phase\u003c\/strong\u003e — ideal for commercial buildings or large 3‑phase residential systems needing reliable backup power. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"390\" data-end=\"657\"\u003e\u003cstrong data-start=\"390\" data-end=\"430\"\u003eQ: What applications is it best for?\u003c\/strong\u003e\u003cbr data-start=\"430\" data-end=\"433\"\u003eA: Engineered for \u003cstrong data-start=\"451\" data-end=\"515\"\u003ecommercial, industrial and large residential 3‑phase service\u003c\/strong\u003e, providing consistent backup for motors, HVAC, servers, lighting, and essential loads during outages. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"659\" data-end=\"859\"\u003e\u003cstrong data-start=\"659\" data-end=\"698\"\u003eQ: What fuel options are supported?\u003c\/strong\u003e\u003cbr data-start=\"698\" data-end=\"701\"\u003eA: Runs on \u003cstrong data-start=\"712\" data-end=\"750\"\u003enatural gas or liquid propane (LP)\u003c\/strong\u003e with simple field conversion while maintaining emissions compliance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"861\" data-end=\"1088\"\u003e\u003cstrong data-start=\"861\" data-end=\"913\"\u003eQ: Does it support remote monitoring and alerts?\u003c\/strong\u003e\u003cbr data-start=\"913\" data-end=\"916\"\u003eA: Yes — it integrates with \u003cstrong data-start=\"944\" data-end=\"991\"\u003eKOHLER® Energy Management App (App Connect)\u003c\/strong\u003e for real‑time status alerts, monitoring and diagnostics. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1090\" data-end=\"1306\"\u003e\u003cstrong data-start=\"1090\" data-end=\"1144\"\u003eQ: How fast does it restore power after an outage?\u003c\/strong\u003e\u003cbr data-start=\"1144\" data-end=\"1147\"\u003eA: Automatically restores power within ~\u003cstrong data-start=\"1187\" data-end=\"1201\"\u003e10 seconds\u003c\/strong\u003e when paired with an automatic transfer switch (sold separately). \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1308\" data-end=\"1615\"\u003e\u003cstrong data-start=\"1308\" data-end=\"1367\"\u003eQ: What engine and power quality features are included?\u003c\/strong\u003e\u003cbr data-start=\"1367\" data-end=\"1370\"\u003eA: Features a \u003cstrong data-start=\"1384\" data-end=\"1425\"\u003e2.2 L liquid‑cooled industrial engine\u003c\/strong\u003e, a \u003cstrong data-start=\"1429\" data-end=\"1453\"\u003ebrushless alternator\u003c\/strong\u003e, advanced voltage\/Hz regulation, and an \u003cstrong data-start=\"1494\" data-end=\"1521\"\u003eRDC2 digital controller\u003c\/strong\u003e for stable and clean power with ultra‑low distortion. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1617\" data-end=\"1867\"\u003e\u003cstrong data-start=\"1617\" data-end=\"1652\"\u003eQ: How quiet and durable is it?\u003c\/strong\u003e\u003cbr data-start=\"1652\" data-end=\"1655\"\u003eA: Built with a \u003cstrong data-start=\"1671\" data-end=\"1711\"\u003esound‑attenuating aluminum enclosure\u003c\/strong\u003e, corrosion‑resistant finish, and quieter cooling system (~≤61 dB during operation), plus high wind load resistance.\u003c\/p\u003e\n\u003ch5\u003e\n\u003cbr\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"6jjgw6\" data-start=\"251\" data-end=\"395\"\u003e\n\u003cstrong data-start=\"253\" data-end=\"278\"\u003eOil \u0026amp; Filter Changes:\u003c\/strong\u003e Replace engine oil and filters every 100–200 hours or annually to prevent engine wear and ensure smooth operation.\u003c\/li\u003e\n\u003cli data-section-id=\"1y9b77i\" data-start=\"396\" data-end=\"516\"\u003e\n\u003cstrong data-start=\"398\" data-end=\"425\"\u003eApp Connect Monitoring:\u003c\/strong\u003e Track performance, receive alerts, and detect issues remotely for proactive maintenance.\u003c\/li\u003e\n\u003cli data-section-id=\"zde58w\" data-start=\"517\" data-end=\"651\"\u003e\n\u003cstrong data-start=\"519\" data-end=\"543\"\u003eCoolant System Care:\u003c\/strong\u003e Maintain proper coolant levels and flush periodically to prevent overheating of the liquid-cooled engine.\u003c\/li\u003e\n\u003cli data-section-id=\"jm709\" data-start=\"652\" data-end=\"781\"\u003e\n\u003cstrong data-start=\"654\" data-end=\"683\"\u003eAir Filter \u0026amp; Spark Plugs:\u003c\/strong\u003e Clean or replace regularly to maintain efficient combustion, reliable starts, and fuel economy.\u003c\/li\u003e\n\u003cli data-section-id=\"c3tl4z\" data-start=\"782\" data-end=\"901\"\u003e\n\u003cstrong data-start=\"784\" data-end=\"810\"\u003eWeekly Exercise Cycle:\u003c\/strong\u003e Automatic test runs keep internal components lubricated and generator ready for outages.\u003c\/li\u003e\n\u003cli data-section-id=\"1r505e9\" data-start=\"902\" data-end=\"1026\"\u003e\n\u003cstrong data-start=\"904\" data-end=\"921\"\u003eLoad Testing:\u003c\/strong\u003e Run under actual or simulated load to ensure stable voltage, frequency, and full-capacity performance.\u003c\/li\u003e\n\u003cli data-section-id=\"1bx48gd\" data-start=\"1027\" data-end=\"1136\"\u003e\n\u003cstrong data-start=\"1029\" data-end=\"1059\"\u003eFuel System Check (NG\/LP):\u003c\/strong\u003e Ensure consistent fuel supply and clean lines for uninterrupted operation.\u003c\/li\u003e\n\u003cli data-section-id=\"fqvysq\" data-start=\"1137\" data-end=\"1245\"\u003e\n\u003cstrong data-start=\"1139\" data-end=\"1176\"\u003eBattery \u0026amp; Electrical Connections:\u003c\/strong\u003e Check battery charge and terminals for reliable automatic startup.\u003c\/li\u003e\n\u003cli data-section-id=\"1qtj1tr\" data-start=\"1246\" data-end=\"1389\"\u003e\n\u003cstrong data-start=\"1248\" data-end=\"1274\"\u003eEnclosure Maintenance:\u003c\/strong\u003e Keep the corrosion-resistant aluminum enclosure clean and ventilated to prevent overheating and extend lifespan.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kohler","offers":[{"title":"Default Title","offer_id":45506021425289,"sku":"24RCLA-QS4","price":17899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0759\/2443\/9177\/files\/7425002930365-IND_Template-removebg_3_633bfdaf-b0f1-4a0c-b442-58dbd71c8a83.webp?v=1775896437","url":"https:\/\/paw-counter.com\/products\/kohler-24rcla-qs4-23kw-277-480v-3-phase-standby-generator-with-app-connect-new","provider":"Paw Counter","version":"1.0","type":"link"}