{"product_id":"kohler-24rcla-qs3-23kw-120-240v-3-phase-standby-generator-with-app-connect-new","title":"Kohler  23KW 120\/240V 3-Phase Standby Generator with App Connect New -  24RCLA-QS3","description":"\u003ch2\u003e\u003cspan\u003eKohler  23KW 120\/240V 3-Phase Standby Generator with App Connect New -  24RCLA-QS3\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eReliable power for large residential or small business needs. When the power goes out during a bad storm or power failure, your 23 kW KOHLER generator with industrial-grade engine keeps your home or business – from central air to sump pump to personal computers – up and running.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"xaz4yd\" data-start=\"29\" data-end=\"298\"\u003e\n\u003cstrong data-start=\"31\" data-end=\"63\"\u003eRobust 3-phase standby power\u003c\/strong\u003e\u003cbr data-start=\"63\" data-end=\"66\"\u003eThis \u003cstrong data-start=\"73\" data-end=\"100\"\u003e23 kW (LP) \/ 21 kW (NG)\u003c\/strong\u003e generator delivers \u003cstrong data-start=\"120\" data-end=\"152\" data-is-only-node=\"\"\u003e120\/240 V three-phase backup\u003c\/strong\u003e suited for \u003cstrong data-start=\"164\" data-end=\"226\"\u003elarge homes, small businesses, shops, and commercial loads\u003c\/strong\u003e needing balanced, reliable power. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"3cr8d\" data-start=\"300\" data-end=\"546\"\u003e\n\u003cstrong data-start=\"302\" data-end=\"336\"\u003eSmart app-connected monitoring\u003c\/strong\u003e\u003cbr data-start=\"336\" data-end=\"339\"\u003eContinuous remote monitoring via the \u003cstrong data-start=\"378\" data-end=\"410\"\u003eKohler Energy Management App\u003c\/strong\u003e lets you receive \u003cstrong data-start=\"428\" data-end=\"467\" data-is-only-node=\"\"\u003ereal-time alerts and status updates\u003c\/strong\u003e, improving visibility and peace of mind. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"wm9hk7\" data-start=\"548\" data-end=\"815\"\u003e\n\u003cstrong data-start=\"550\" data-end=\"600\"\u003ePremium power quality \u0026amp; electronics protection\u003c\/strong\u003e\u003cbr data-start=\"600\" data-end=\"603\"\u003eBrushless alternator with advanced voltage\/Hz regulation produces \u003cstrong data-start=\"671\" data-end=\"720\"\u003eclean, stable power with ultra-low distortion\u003c\/strong\u003e, safeguarding sensitive electronics and control systems. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bgkpc3\" data-start=\"817\" data-end=\"1046\"\u003e\n\u003cstrong data-start=\"819\" data-end=\"865\"\u003eIndustrial-grade liquid-cooled performance\u003c\/strong\u003e\u003cbr data-start=\"865\" data-end=\"868\"\u003eThe \u003cstrong data-start=\"874\" data-end=\"904\"\u003e2.2 L liquid-cooled engine\u003c\/strong\u003e runs at 1800 RPM for \u003cstrong data-start=\"926\" data-end=\"963\" data-is-only-node=\"\"\u003equieter, more efficient operation\u003c\/strong\u003e and long-term reliability under heavy loads. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xhcxpq\" data-start=\"1048\" data-end=\"1276\"\u003e\n\u003cstrong data-start=\"1050\" data-end=\"1086\"\u003eDurable, weather-ready enclosure\u003c\/strong\u003e\u003cbr data-start=\"1086\" data-end=\"1089\"\u003eSound-attenuating aluminum housing with corrosion-resistant finish keeps noise low (~61 dB @ 7 m) and ensures \u003cstrong data-start=\"1201\" data-end=\"1237\"\u003edurability in harsh environments\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"v843cd\" data-start=\"1278\" data-end=\"1479\"\u003e\n\u003cstrong data-start=\"1280\" data-end=\"1319\"\u003eEasy installation \u0026amp; NFPA compliance\u003c\/strong\u003e\u003cbr data-start=\"1319\" data-end=\"1322\"\u003eMeets \u003cstrong data-start=\"1330\" data-end=\"1370\"\u003eNFPA 37 reduced setback requirements\u003c\/strong\u003e, allowing installation within 18″ of structures (ATS sold separately)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e\n\u003cbr\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-start=\"93\" data-end=\"342\"\u003e\u003cstrong data-start=\"93\" data-end=\"137\"\u003eQ1: What is this generator designed for?\u003c\/strong\u003e\u003cbr data-start=\"137\" data-end=\"140\"\u003eA: A 23 kW 120\/240 V 3-phase standby generator is built for large residential, commercial, or small business backup power needs with three-phase electrical service. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"344\" data-end=\"586\"\u003e\u003cstrong data-start=\"344\" data-end=\"403\"\u003eQ2: Does it automatically restore power during outages?\u003c\/strong\u003e\u003cbr data-start=\"403\" data-end=\"406\"\u003eA: Yes — when connected to an automatic transfer switch (sold separately), it starts and restores power automatically during utility failures. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"588\" data-end=\"788\"\u003e\u003cstrong data-start=\"588\" data-end=\"628\"\u003eQ3: What fuel types does it support?\u003c\/strong\u003e\u003cbr data-start=\"628\" data-end=\"631\"\u003eA: It runs on natural gas or liquid propane (LP) with simple field conversion while maintaining emission certification. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"790\" data-end=\"995\"\u003e\u003cstrong data-start=\"790\" data-end=\"838\"\u003eQ4: What is App Connect \/ remote monitoring?\u003c\/strong\u003e\u003cbr data-start=\"838\" data-end=\"841\"\u003eA: Real-time alerts and system status are available through the KOHLER® Energy Management App for remote monitoring. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"997\" data-end=\"1149\"\u003e\u003cstrong data-start=\"997\" data-end=\"1036\"\u003eQ5: How much power does it deliver?\u003c\/strong\u003e\u003cbr data-start=\"1036\" data-end=\"1039\"\u003eA: Rated at ~23 kW on LP and ~21 kW on natural gas at 120\/240 V 3-phase. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1151\" data-end=\"1405\"\u003e\u003cstrong data-start=\"1151\" data-end=\"1213\"\u003eQ6: Is the power quality suitable for sensitive equipment?\u003c\/strong\u003e\u003cbr data-start=\"1213\" data-end=\"1216\"\u003eA: Yes — advanced voltage\/Hz regulation and a brushless alternator deliver clean power with ultra-low total harmonic distortion to protect electronics. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1407\" data-end=\"1626\"\u003e\u003cstrong data-start=\"1407\" data-end=\"1443\"\u003eQ7: How quiet and durable is it?\u003c\/strong\u003e\u003cbr data-start=\"1443\" data-end=\"1446\"\u003eA: The sound-attenuating aluminum enclosure with internal silencer keeps noise under ~61 dB at 7 m and resists corrosion, fade, and scratches. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1628\" data-end=\"1858\"\u003e\u003cstrong data-start=\"1628\" data-end=\"1685\"\u003eQ8: What engine and controller features are included?\u003c\/strong\u003e\u003cbr data-start=\"1685\" data-end=\"1688\"\u003eA: It features a 2.2 L liquid-cooled engine with RDC2 digital controller for advanced control, diagnostics, and weekly self-testing.\u003c\/p\u003e\n\u003ch5\u003e\n\u003cbr\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"ivxym2\" data-start=\"101\" data-end=\"221\"\u003e\n\u003cstrong data-start=\"103\" data-end=\"132\"\u003eRun Weekly Exercise Cycle\u003c\/strong\u003e\u003cbr data-start=\"132\" data-end=\"135\"\u003ePerform automatic self-test (~20–30 min) to keep engine lubricated and system ready.\u003c\/li\u003e\n\u003cli data-section-id=\"dus7bg\" data-start=\"223\" data-end=\"364\"\u003e\n\u003cstrong data-start=\"225\" data-end=\"261\"\u003eChange Oil \u0026amp; Filters on Schedule\u003c\/strong\u003e\u003cbr data-start=\"261\" data-end=\"264\"\u003eReplace engine oil, oil filter, and air filter at recommended intervals for long-term reliability.\u003c\/li\u003e\n\u003cli data-section-id=\"ve4wlh\" data-start=\"366\" data-end=\"478\"\u003e\n\u003cstrong data-start=\"368\" data-end=\"395\"\u003eInspect Battery Monthly\u003c\/strong\u003e\u003cbr data-start=\"395\" data-end=\"398\"\u003eCheck charge level, terminals, and corrosion to ensure fast automatic startup.\u003c\/li\u003e\n\u003cli data-section-id=\"cfu9fz\" data-start=\"480\" data-end=\"599\"\u003e\n\u003cstrong data-start=\"482\" data-end=\"513\"\u003eMonitor Fuel System (NG\/LP)\u003c\/strong\u003e\u003cbr data-start=\"513\" data-end=\"516\"\u003eVerify fuel pressure, regulators, and connections for stable 3-phase performance.\u003c\/li\u003e\n\u003cli data-section-id=\"pnqbfk\" data-start=\"601\" data-end=\"723\"\u003e\n\u003cstrong data-start=\"603\" data-end=\"635\"\u003eClean Air Intake \u0026amp; Enclosure\u003c\/strong\u003e\u003cbr data-start=\"635\" data-end=\"638\"\u003eKeep vents clear of dust and debris to prevent overheating and airflow restriction.\u003c\/li\u003e\n\u003cli data-section-id=\"j1yb4z\" data-start=\"725\" data-end=\"841\"\u003e\n\u003cstrong data-start=\"727\" data-end=\"759\"\u003eTest Under Load Periodically\u003c\/strong\u003e\u003cbr data-start=\"759\" data-end=\"762\"\u003eSimulate real demand to confirm voltage stability and proper phase balancing.\u003c\/li\u003e\n\u003cli data-section-id=\"19vme1i\" data-start=\"843\" data-end=\"956\"\u003e\n\u003cstrong data-start=\"845\" data-end=\"875\"\u003eUse App Connect Monitoring\u003c\/strong\u003e\u003cbr data-start=\"875\" data-end=\"878\"\u003eTrack alerts, runtime, and system health remotely for proactive maintenance.\u003c\/li\u003e\n\u003cli data-section-id=\"18nwm35\" data-start=\"958\" data-end=\"1074\"\u003e\n\u003cstrong data-start=\"960\" data-end=\"994\"\u003eInspect Electrical Connections\u003c\/strong\u003e\u003cbr data-start=\"994\" data-end=\"997\"\u003eTighten breakers, terminals, and transfer switch wiring for safe operation.\u003c\/li\u003e\n\u003cli data-section-id=\"7sncf4\" data-start=\"1076\" data-end=\"1176\"\u003e\n\u003cstrong data-start=\"1078\" data-end=\"1115\"\u003eCheck Cooling \u0026amp; Engine Components\u003c\/strong\u003e\u003cbr data-start=\"1115\" data-end=\"1118\"\u003eLook for leaks, wear, or blockage affecting performance.\u003c\/li\u003e\n\u003cli data-section-id=\"1b6isn\" data-start=\"1178\" data-end=\"1281\"\u003e\n\u003cstrong data-start=\"1180\" data-end=\"1220\"\u003eSchedule Annual Professional Service\u003c\/strong\u003e\u003cbr data-start=\"1220\" data-end=\"1223\"\u003eEnsures warranty compliance and peak system reliability.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kohler","offers":[{"title":"Default Title","offer_id":45506021458057,"sku":"24RCLA-QS3","price":17899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0759\/2443\/9177\/files\/7425001291965-IND_Template-removebg_3_f1ee3c6e-078d-4c92-8ca8-695ede0cc59a.webp?v=1775896438","url":"https:\/\/paw-counter.com\/products\/kohler-24rcla-qs3-23kw-120-240v-3-phase-standby-generator-with-app-connect-new","provider":"Paw Counter","version":"1.0","type":"link"}